Performance testing for high-load and distributed systems
Midair runs the same load on the same bench each time. Every run records its measurements in the log and stays a separate record.
A performance number means little on its own. It means something next to the same number from the previous build, measured the same way.
- load
- wrk · 4 threads · 256 connections · 60 s
- requests
- 41 230 req/s
- latency
- p50 1.9 ms · p99 9.1 ms
- energy
- 408 J over 60 s · avg 6.8 W · peak 9.4 W
- bench
- lab-2 · 3 hosts · lock 9c41e07
- record
- run 312 · kept with its configuration
What performance testing is.Numbers under a known load.
Performance testing measures how a system behaves under load: its throughput, its latency, the requests it serves per second and the energy it uses.
Load testing checks the load the system is expected to carry. Stress testing goes past that point to find where the system breaks and how.
On devices and networks, the bench matters as much as the code. The same build gives different numbers on another host, link or power supply.
What a run measures.Choose a kind of measurement.
Throughput
Bits or packets per second through a link, a device or a service. iperf and iperf3 sit behind one interface, so a test can switch tools without a rewrite.
- Tools
iperf, iperf3, netperf, TRex- In the run log
throughput mean 912 Mbit/s min 884 max 931 iperf3 · TCP · 8 streams · 60 s · Example
Latency
Round-trip time and request latency, recorded as a median and percentiles. The tail usually moves before the median does.
- Tools
wrk, ping, netperf, sfnt-pingpong- In the run log
rtt median 0.41 ms p99 1.90 ms stdev 0.22 ms sfnt-pingpong · UDP · 64 bytes · Example
Requests
Requests and connections per second against HTTP servers, Redis and memcached.
- Tools
wrk, redis-benchmark, memtier, memaslap- In the run log
rps 41 230 req/s cps 2 950 conn/s wrk · 256 connections · 60 s · Example
Energy
Energy over the test window in joules and milliwatt-hours, with average and peak power. It works with SCPI bench instruments and the PPK2, Joulescope, Otii and Monsoon profilers.
- Tools
tsf-power- In the run log
energy 408 J (113.3 mWh) over 60 s power avg 6.8 W peak 9.4 W tsf-power · Joulescope · Example
A test writes each value into the Test Environment log as a measurement, with its unit and how it was aggregated: minimum, mean, median, percentile or a full series.
Compare two builds.Same load, same bench, one change.
An example chart drawn from two recorded runs of the same test. Move the slider or point at the chart to read each load step.
- Connections
- 256
- build 2.4.0
- 4.8 ms
- build 2.4.1
- 9.1 ms
- Change
- +90%
Midair has no screen that compares two runs. Each run is a separate record, with its measurements in its own log. If you publish runs to Bublik, its history view charts a measurement across runs.
Show the numbers
| Connections | build 2.4.0, ms | build 2.4.1, ms | Change |
|---|---|---|---|
| 32 | 2.1 | 2.0 | -5% |
| 64 | 2.2 | 2.1 | -5% |
| 96 | 2.4 | 2.3 | -4% |
| 128 | 2.6 | 2.5 | -4% |
| 160 | 2.9 | 2.9 | 0% |
| 192 | 3.3 | 3.6 | +9% |
| 224 | 3.9 | 5.4 | +38% |
| 256 | 4.8 | 9.1 | +90% |
| 288 | 6.2 | 14.8 | +139% |
| 320 | 8.4 | 22.6 | +169% |
What keeps two runs comparable.Five things each record pins down.
The code
builder.conf.lock records the exact commit of the suite and of every library it builds.
The bench
Per-bench env and run.conf files name the hosts, interfaces and instruments the run uses.
The expected result
trc.xml holds the expected verdict for each test. A test fails when its measurement crosses the limit it checks.
Several hosts, one run
Test Environment coordinates load generators and receivers on several hosts in one run, with one log.
A new record every time
Every start is a new record with its own configuration. Midair never writes over an earlier run.
Further reading.From our engineering work.
Questions.Short answers.
What is performance testing?
Performance testing measures how a system behaves under load: its throughput, its latency and the resources it uses as the load grows.
What is the difference between load testing and stress testing?
Load testing checks how the system performs under the traffic it is expected to carry. Stress testing pushes past that point to find where the system breaks and how it behaves while it breaks.
Which load tools can a test drive?
Test Environment has ready wrappers for iperf, iperf3, netperf, TRex, wrk, redis-benchmark, memtier, memaslap, sfnt-pingpong and stress. A test starts them on the agent hosts and reads their results.
Can Midair compare two builds?
Not on one screen. You run the same suite on both builds, and each run keeps its measurements in its own record. If you publish runs to Bublik, its history view charts a measurement across runs.
Can we measure energy use?
Yes. tsf-power measures the energy a device uses over a test window, with SCPI bench instruments or USB profilers such as PPK2, Joulescope, Otii and Monsoon.
Does it fit our CI?
Yes. Runs start from your CI, for example with the Jenkins plugin. An AI assistant can start runs and read failures through MCP.
Start with one workload on one bench.Then measure every build the same way.
Compare the plans on the pricing page. Prices are monthly, in euros.